Three-phase AC/DC DIN rail power supplies offer a +50% boost power rating

15-02-2024 | TDK | Power

TDK Corporation has added higher power, three-phase AC input models to the TDK-Lambda DRB series of DIN rail mount power supplies. With 24V, 48V and 72V outputs, the products are rated for continuous operation at 480W or 960W and can supply a boost of 720W and 1440W respectively for up to seven seconds. This, and a constant current overload characteristic, allows operation with capacitive and inductive loads. These power supplies also provide a very low energy inrush current upon initial start-up, decreasing nuisance tripping of input circuit breakers. The series can be employed in a wide range of applications, including conventional switch cabinets, stand-alone machinery, and industrial systems, as well as information and communications technology.

The units have a wide input range of 350VAC to 575VAC and are housed in a rugged metal enclosure with dimensions of 65mm (width) x 129mm (height) x 159.3mm (depth) for the 480W models and 100mm (width) x 129mm (height) x 171.9mm (depth) for the 960W. This saves space on the DIN rail for other components and reduces cost. A selection of screw terminals or push-in connectors are obtainable for the input and output wiring. The DRB480 and 960 models have a high operating efficiency of up to 96.3% and a low stand-by power consumption of <2.3W when using the remote on-off function (inhibit). This lowers energy usage and contributes to a lower CO2 footprint of the entire system. Lower losses also decrease internal heating inside the power supplies, preventing electrolytic capacitor dry-out for long field life.

For higher power or redundant systems, the front panel DIP switch allows droop mode current sharing for parallel operation. These new models have a wide adjustment range of 22.5V to 29V (24V nominal), 45V to 56V (48V nominal) and 70V to 85V (72V nominal) to allow compensation for cable drops, ORing FETs or setting to non-standard output voltages. As well as two LED indicators, a DC OK relay contact is offered for remote monitoring and remote on/off is possible by applying an external voltage to the inhibit relay contact.

Input to output isolation is 3,510VAC, input to ground 2,210VAC and output to ground is 1,390VAC. The models are convection cooled and rated for operation in -25C to +70C ambient temperatures, with derating above 55C.

The units are certified to IEC/EN/UL/CSA 62368-1, 61010-1, 61010-2-201 and are CE / UKCA marked to the Low Voltage, EMC and RoHS Directives. They meet EN 55011-B and CISPR11-B radiated and conducted emissions. The series also complies with EN 61000-3-2 (Class A) harmonic currents and IEC/EN 61000-6-2 immunity standards.

sebastian_springall.jpg

By Seb Springall

Seb Springall is a seasoned editor at Electropages, specialising in the product news sections. With a keen eye for the latest advancements in the tech industry, Seb curates and oversees content that highlights cutting-edge technologies and market trends.